Estimated Lead Time : 4-6 Weeks
Manufacturer : Endress+Hauser
PMP55AA12QA1MGJTJJA4A
metallic process isolating diaphragm for gauge pressure
Approval : AA : Non-hazardous area
Output : 1 : 4-20mA
Display, Operation : 2 : W/o LCD, push button on electronics
Housing : Q : F15 stainless steel hygiene
Electrical Connection : A : Gland M20, IP66/68 NEMA4X/6P
Sensor Range : 1M : 4bar/400kPa/60psi gauge, 40mH2O/133ftH2O overload: 28bar/ 2.8MPa/420psi
Reference Accurancy : G: Standard
Calibration; Unit : J: Customised pressure; see addition spec.
Process Connection : TJJ : Tri-Clamp ISO2852 DN38 (1-1/2″), 316L, DIN32676 DN40, EHEDG, 3A, ASME-BPE
Membrane Material : A: 316L
Fill Fluid: 4 : Vegerable oil FDA
Diaphragm Seal Connection : A : Direct
Compressibility factor 999
Low range value 0 bar
Upper range value 4.00000 bar
Min. low range value -1.03500 bar
Max. low range value 4.20000 bar
Min. upper range value -1.03500 bar
Max. upper range value 4.20000 bar
Span limit minimal 0.20000 bar
Span 4.00000 bar
Span limit maximal 5.20000 bar
Turndown error 20.00000 Turndown information 10.00000 Min. upper range value 2 0.40000 bar
Maximum working pressure(MWP) 18.70000 bar
Overpressure single side 28.00000 bar
Max. pressure 28.00000 bar
Low range value -1 bar Upper range value 4 bar
2nd value display none Dampings 2 Maximum working pressure (MWP) 40.00000 bar
Overpressure single side 60.00000 bar
Max. pressure 60.00000 bar
Min. upper range value 0.04000 bar
Absolute and gauge pressure Cerabar PMP55
Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids
Large variety of different process connections and membrane materials
New TempC Membrane minimizes influences of ambient and process temperature fluctuations
Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Single chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -70 to +400°C (-94 to +752°F)
Measuring ranges: -1/0 up to +400bar (-15/0 up to +6,000psi)
Accuracy: ± 0.15%, “Platinum” ± 0.075%
International explosion protection certificates, SIL, hygienic approvals, marine approvals
Shipping Weight : 4.5 Kg
Download PDF File PMP55