Estimated Lead Time : 3-5 Weeks
Manufacturer : Schmersal
RSS16-I2-SD-ST8H
Ordering data
Article number (order number) : 103009528
EAN (European Article Number) : 4030661462189
eCl@ss number, version 11.0 : 27-27-24-03
eCl@ss number, version 9.0 : 27-27-24-03
ETIM number, version 7.0 : EC000030
ETIM number, version 6.0 : EC000030
Approvals – Standards
Certificates : TÜV, cULus, FCC, IC, UKCA
General data
Standards : EN IEC 60947-5-3
Coding : Individual coding, multiple teaching
Coding level according to EN ISO 14119 : High
Working principle : RFID
Housing construction form : Block
Installation conditions (mechanical) : not flush
Sensor topology : Sensor for series wiring
Enclosure material : Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active area : Glass-fibre, reinforced thermoplastic
Reaction time, maximum : 100 ms
Duration of risk, maximum : 200 ms
General data – Features
Serial diagnostics : Yes
Short circuit detection : Yes
Cross-circuit detection : Yes
Series-wiring : Yes
Safety functions : Yes
Cascadable : Yes
Integral system diagnostics, status : Yes
Number of LEDs : 2
Number of semi-conductor outputs with signaling function : 1
Number of fail-safe digital outputs : 2
Number of series-wiring of sensors : 31
Safety classification
Standards : EN ISO 13849-1, EN IEC 61508
Performance Level, up to : e
Category : 4
PFH value : 6.30 x 10?¹¹ /h
PFD value : 1.50 x 10?5
Safety Integrity Level (SIL), suitable for applications in : 3
Mission time : 20 Year(s)
Mechanical data
Actuating panels : front side, rear, from head
Active area : lateral, front side, cover-side
Mounting : 2 x M5, Cylinder head screw
Tightening torque of the fixing screws : 2 Nm
Mechanical data – Switching distances according EN IEC 60947-5-3
Switch distance, typical : 15 mm
Assured switching distance “ON” Sao : 5 mm
Assured switching distance “OFF” Sar : 30 mm
Hysteresis (Switching distance), maximum : 2 mm
Repeat accuracy R : 0.5 mm
Mechanical data – Connection technique
Note (length of the sensor chain) : Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring) : Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Cable entry : M12 (A-coding)
Termination : Connector M12, 8-pole
Mechanical data – Dimensions
Length of sensor : 91 mm
Width of sensor : 52 mm
Height of sensor : 30 mm
Ambient conditions
Degree of protection : IP65, IP67, IP66
Ambient temperature : -25 … +70 °C
Storage and transport temperature, minimum : -25 °C
Storage and transport temperature, maximum : +85 °C
Relative humidity, maximum : 93 %
Note (Relative humidity) : non-condensing, non-icing
Restistance to shock : 30 g / 11 ms
Permissible installation altitude above sea level, maximum : 2,000 m
Ambient conditions – Insulation values
Rated insulation voltage Ui : 32 VDC
Rated impulse withstand voltage Uimp : 0.8 kV
Overvoltage category : III
Degree of pollution : 3
Electrical data
Operating voltage : 24 VDC -15 % / +10 %
Operating current, minimum : 0.5 mA
No-load supply current I0, typical : 100 mA
Rated operating voltage : 24 VDC
Operating current : 2,100 mA
Required rated short-circuit current : 100 A
Time to readiness, maximum : 2,000 ms
Switching frequency, maximum : 1 Hz
Electrical data – Safety digital inputs
Current consumption of the safety inputs : 5 mA
Electrical data – Safety digital outputs
Rated operating current (safety outputs) : 1,000 mA
Output current, (fail-safe output), maximum : 1 A
Design of control elements : p-type
Voltage drop Ud, maximum : 1 V
Leakage current Ir, maximum : 0.5 mA
Voltage, Utilisation category DC-12 : 24 VDC
Current, Utilisation category DC-12 : 1 A
Voltage, Utilisation category DC-13 : 24 VDC
Current, Utilisation category DC-13 : 1 A
Electrical data – Diagnostic outputs
Operating current : 50 mA
Design of control elements : p-type
Voltage drop Ud, maximum : 2 V
Voltage, Utilisation category DC-12 : 24 VDC
Current, Utilisation category DC-12 : 0.05 A
Voltage, Utilisation category DC-13 : 24 VDC
Current, Utilisation category DC-13 : 0.05 A
Electrical data – Serial diagnostic SD
Designation, Serial diagnostic SD : OUT
Operation current : 150 mA
Design of control elements : short-circuit proof, p-type
Wiring capacitance : 50 nF
Electrical data – Electromagnetic compatibility (EMC)
Interfering radiation : IEC 61000-6-4
EMC rating : IEC 60947-3
Status indication
Note (LED switching conditions display) :
Multi-coloured LED: Green, Red
LED yellow: Operating condition
LED green: Supply voltage
LED red: Fault
Scope of delivery : Actuator must be ordered separately.
Accessory
Recommendation (actuator) : RST16-1, RST16-1-R
Recommended safety switchgear : PROTECT PSC1
Weight : 0.28 Kg
Shipping Weight : 1.0 Kg



Reviews