1042022 SICK Sensors CLV640-6000 Bar code scanners CLV64x / Standard Density

Original price was: $6,614.00.Current price is: $4,629.80.

10 in stock

SKU: CLV640-6000 Category:
Guaranteed Safe Checkout

Estimated Lead Time : 4-6 Weeks

Manufacturer : SICK Sensors

Bar code scanners CLV64x / Standard Density

Type : CLV640-6000

Part number : 1042022

Version : Standard Density

Connection type : Cable

Reading field : Oscillating mirror

Scanner design : Line scanner

Focus : Dynamic focus control

Light source : Visible red light (655 nm)

Light spot : Circular

MTBF : 40,000 h

Laser class : 2 (IEC 60825-1:2014, EN 60825-1:2014)

Aperture angle : = 50°

Scanning frequency : 400 Hz…1,200 Hz

Code resolution : 0.2 mm…1 mm

Reading distance : 45 mm…755 mm 1)

Oscillating mirror functions : Fixed (adjustable position), oscillating (variable or fixed amplitude), one shot

Oscillation frequency : 0.5 Hz…6.25 Hz

Angle of deflection : –20°…20°

1) For details see reading field diagram.

PERFORMANCE :-

Bar code types : All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey

Print ratio : 2:1…3:1

No. of codes per scan : 1…20 (Standard decoder) : 1…6 (SMART decoder)

No. of codes per reading interval : 1…50 (auto-discriminating)

No. of characters per reading interval : 5,000 : 500 (for multiplexer function in CAN operation)

No. of multiple readings : 1…99

INTERFACES :-

PROFINET : Yes

Function : PROFINET Dual Port (optional via external connection module CDF600-2)

EtherCAT® : Yes

Type of fieldbus integration : Optional over external fieldbus module CDF600

Serial : Yes , RS-232, RS-422, RS-485

Function : Host, AUX

Data transmission rate : 2,400 Baud…115.2 kBaud, AUX: 57.6 kBaud (RS-232)

CAN : Yes

Function : SICK CAN sensor network CSN (master/slave, multiplexer/server)

Data transmission rate : 20 kbit/s…1 Mbit/s

CANopen : Yes

Data transmission rate : 20 kbit/s…1 Mbit/s

PROFIBUS DP : Yes

Type of fieldbus integration : Optional over external fieldbus module CDF600-2

DeviceNet™ Yes

Type of fieldbus integration Optional, over external connection module CDM + CMF

Switching inputs : 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)

Switching outputs : 4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420)

Reading pulse : Switching inputs, non-powered, serial interface, auto pulse, CAN

Optical indicators : 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))

Acoustic indicators : Beeper/buzzer (can be switched off, can be allocated as a result indication function)

Operating elements : 2 buttons (choose and start/stop functions)

Configuration software : SOPAS ET

Memory card : MicroSD memory card (flash card), optional

MECHANICS/ELECTRONICS :-

Electrical connection : 1 x 15-pin D-Sub HD male connector (0.9 m)

Operating voltage : 18 V DC…30 V DC

Power consumption : 6.5 W

Housing : Aluminum die cast

Housing color : Light blue (RAL 5012)

Front screen : Glass

Enclosure rating : IP65 (EN 60529)

Protection class : III (EN 61140)

Weight : 420 g, with connecting cable

Dimensions (L x W x H) : 95 mm x 107 mm x 41 mm

AMBIENT DATA:-

Electromagnetic compatibility (EMC) : EN 61000-6-3 (2001-10) / EN 61000-6-2:2005

Vibration resistance : EN 60068-2-6 (1995)

Shock resistance : EN 60068-2-27 (1993)

Ambient operating temperature : 0 °C…+40 °C

Storage temperature : –20 °C…+70 °C

Permissible relative humidity : 90 %, Non-condensing

Ambient light immunity : 2,000 lx, on bar code

Bar code print contrast (PCS) : = 60 %

GENERAL NOTES :-

Note on use : For Ethernet connection please use an Ethernet version of CLV6xx

Shipping Weight : 1.4 Kg

Reviews

There are no reviews yet.

Be the first to review “1042022 SICK Sensors CLV640-6000 Bar code scanners CLV64x / Standard Density”

Your email address will not be published. Required fields are marked *