Estimated Lead Time : Usually ships in 1-10 working days.
Manufacturer : Schneider Electric
EMERGENCY STOP TRIP WIRE SWITCH WITHOUT
Part Number : XY2CH13390
Range of product
Telemecanique Emergency stop rope pull switches XY2C
Product or component type
Latching emergency stop rope pull switch
device short name
XY2CH
Housing colour
Red RAL 3000
Overvoltage category
Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030
Local signalling
With pilot light, yellow, 24 V
Number of cables
1
Trigger cable maximum length
30 m
Body material
Zamak
Cover material
Stainless steel
reset
By mushroom head push-button
[Us] rated supply voltage
24 V
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break
Trigger cable anchor point
RH or LH side
Light block supply
Direct
Connections – terminals
Screw clamp terminal, 1 x 0.5…2 x 1.5 mm²
Tightening torque
0.8…1.2 N.m
Cable entry number
3 tapped entry for Pg 13.5 cable gland
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data
B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
marking
CE
Mechanical durability
800000 cycles
Distance between cable supports
5 m
[Ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
[Uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
Positive opening
With conforming to EN/IEC 60947-5-1
Maximum resistance across terminals
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Short-circuit protection
10 A cartridge fuse type gG conforming to EN/IEC 60269
Terminals description ISO n°1
(13-14)NO
(21-22)NC
Product weight
0.9 kg
Compatibility code
XY2CH
standards
EN/IEC 60204-1
EN/ISO 13850
Work equipment directive 2009/104/EC
EN/IEC 60947-5-1
EN/IEC 60947-5-5
Machinery directive 2006/42/EC
Product certifications
UL category NISD emergency stop devices
Protective treatment
TC
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
50 gn 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.0 cm
Package 1 Width
10.5 cm
Package 1 Length
20.5 cm
Package 1 Weight
952.0 g
Shipping Weight : 2 kg