Manufacturer : Schmersal

RSS 36-D-ST5

Ordering data

Article number (order number) : 103025096

EAN (European Article Number) : 4030661512204

eCl@ss number, version 11.0 : 27-27-24-03

eCl@ss number, version 9.0 : 27-27-24-03

ETIM number, version 7.0 : EC000030

ETIM number, version 6.0 : EC000030

Approvals – Standards

Certificates : TÜV, cULus, ECOLAB, FCC, IC

General data

Standards : EN ISO 13849-1, EN IEC 60947-5-3, EN IEC 61508

Coding : Universal coding

Coding level according to EN ISO 14119 : Low

Working principle : RFID

Frequency band RFID : 125 kHz

Transmitter output RFID, maximum : -6 dB/m

Housing construction form : Block

Installation conditions (mechanical) : not flush

Sensor topology : Individual sensor or end sensor in a series

Enclosure material : Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Active area : Glass-fibre, reinforced thermoplastic

Reaction time, maximum : 100 ms

Duration of risk, maximum : 200 ms

Reaction time, switching off safety outputs via actuator, maximum : 100 ms

Reaction time, switching off safety outputs via safety inputs, maximum : 0.5 ms

General data – Features

Diagnostic output : Yes

Short circuit detection : Yes

Cross-circuit detection : Yes

Safety functions : Yes

Cascadable : Yes

Integral system diagnostics, status : Yes

Number of LEDs : 3

Number of semi-conductor outputs with signaling function : 1

Number of fail-safe digital outputs : 2

Safety classification

Standards : EN ISO 13849-1, EN IEC 61508

Performance Level, up to : e

Category : 4

PFH value : 2.70 x 10?¹° /h

PFD value : 2.10 x 10?5

Safety Integrity Level (SIL), suitable for applications in : 3

Mission time : 20 Year(s)

Mechanical data

Actuating panels : lateral

Active area : lateral

Mechanical life, minimum : 1,000,000 Operations

Note (Mechanical life) : Actuating speed < 0.25 m/s, Operations for door weights ≤ 5 kg Mounting : A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used. Type of the fixing screws : 2x M4 (cylinder head screws with washers DIN 125A / form A) Tightening torque of the fixing screws, minimum : 2.2 Nm Tightening torque of the fixing screws, maximum : 2.5 Nm Mechanical data - Switching distances according EN IEC 60947-5-3 Switch distance, typical : 12 mm Assured switching distance "ON" Sao : 10 mm Assured switching distance "OFF" Sar : 20 mm Hysteresis (Switching distance), maximum : 2 mm Repeat accuracy R : 0.5 mm Note ( Repeat accuracy R ) : Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm. Mechanical data - Connection technique Note (length of the sensor chain) : Cable length and cross-section change the voltage drop dependiing on the output current Termination : Connector M12, 5-pole, A-coded Mechanical data - Dimensions Length of sensor : 22 mm Width of sensor : 106.3 mm Height of sensor : 25 mm Ambient conditions Degree of protection : IP65, IP67, IP69 Ambient temperature : -25 ... +70 °C Storage and transport temperature, minimum : -25 °C Storage and transport temperature, maximum : +85 °C Relative humidity, maximum : 93 % Note (Relative humidity) : non-condensing, non-icing Resistance to vibrations : 10 … 55 Hz, amplitude 1 mm Restistance to shock : 30 g / 11 ms Protection class : III Permissible installation altitude above sea level, maximum : 2,000 m Ambient conditions - Insulation values Rated insulation voltage Ui : 32 VDC Rated impulse withstand voltage Uimp : 0.8 kV Overvoltage category : III Degree of pollution : 3 Electrical data Operating voltage : 24 VDC -15 % / +10 % (stabilised PELV power supply) Operating current, minimum : 0.5 mA No-load supply current I0, typical : 35 mA Rated operating voltage : 24 VDC Operating current : 600 mA Required rated short-circuit current : 100 A Time to readiness, maximum : 2,000 ms Switching frequency, maximum : 1 Hz Electrical data - Safety digital outputs Designation, Safety outputs : Y1 and Y2 Rated operating current (safety outputs) : 250 mA Output current, (fail-safe output), maximum : 0.25 A Design of control elements : short-circuit proof, p-type Voltage drop Ud, maximum : 1 V Leakage current Ir, maximum : 0.5 mA Voltage, Utilisation category DC-12 : 24 VDC Current, Utilisation category DC-12 : 0.25 A Voltage, Utilisation category DC-13 : 24 VDC Current, Utilisation category DC-13 : 0.25 A Test pulse interval, typical : 1000 ms Test pulse duration, maximum : 0.3 ms Classification ZVEI CB24I, Source : C2 Classification ZVEI CB24I, Sink : C1, C2 Electrical data - Diagnostic outputs Designation, Diagnostic outputs : OUT Design of control elements : short-circuit proof, p-type Voltage drop Ud, maximum : 2 V Voltage, Utilisation category DC-12 : 24 VDC Current, Utilisation category DC-12 : 0.05 A Voltage, Utilisation category DC-13 : 24 VDC Current, Utilisation category DC-13 : 0.05 A Electrical data - Electromagnetic compatibility (EMC) Interfering radiation : IEC 61000-6-4 EMC rating : IEC 60947-3 Status indication Note (LED switching conditions display) : LED yellow: Operating condition LED green: Supply voltage LED red: Fault Pin assignment PIN 1 : 1A1 Ue: (1) PIN 2 : Y2 safety output 2: White PIN 3 : A2 GND Blue PIN 4 : Y1 Safety output 1 Black PIN 5 : OUT Diagnostic output OUT Grey Scope of delivery : Actuator must be ordered separately. Accessory Recommendation (actuator) : RST 36-1, RST 36-1-R Recommended safety switchgear : PROTECT PSC1, SRB-E-301ST, SRB-E-201LC Note (General) : Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary. Weight : 0.01 Kg Shipping Weight : 1.0 Kg