TM221M16R Schneider Electric Logic controller, Modicon M221, 16 IO relay

Original price was: $265.00.Current price is: $185.50.

SKU: TM221M16R Category:
Guaranteed Safe Checkout

Estimated Lead Time : 4 – 6 weeks

Manufacturer : Schneider Electric

Logic controller, Modicon M221, 16 IO relay

Main:

Range of product: Modicon M221

Product or component type: Logic controller

[Us] rated supply voltage: 24 V DC

Discrete input number: 8, discrete input conforming to IEC 61131-2 Type 1

Analogue input number: 2 at 0…10 V

Discrete output type: Relay normally open

Discrete output number: 8 relay

Discrete output voltage: 5…125 V DC, 5…250 V AC

Discrete output current: 2 A

Complementary:

Discrete I/O number: 16

Maximum number of I/O expansion module: 7 (local I/O-Architecture), 14 (remote I/O-Architecture)

Supply voltage limits: 20.4…28.8 V

Inrush current: 35 A

Maximum power consumption in W: 22.5 W at 24 V (with max number of I/O expansion module), 3.6 W at 24 V (without I/O expansion module)

Power supply output current: 0.52 A 5 V for expansion bus, 0.46 A 24 V for expansion bus

Discrete input logic: Sink or source (positive/negative)

Discrete input voltage: 24 V

Discrete input voltage type: DC

Analogue input resolution: 10 bits

LSB value: 10 mV

Conversion time: 1 ms per channel + 1 controller cycle time for analogue input analog input

Permitted overload on inputs: +/- 30 V DC for 5 min (maximum) for analog input, +/- 13 V DC (permanent) for analog input

Voltage state 1 guaranteed: >= 15 V for input

Voltage state 0 guaranteed: <= 5 V for input Discrete input current: 7 mA for discrete input, 5 mA for fast input Input impedance: 100 kOhm for analog input, 3.4 kOhm for input, 4.9 kOhm for fast input Response time: 35 µs turn-off, I2...I5 terminal(s) for input 10 ms turn-on for output 10 ms turn-off for output 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input Configurable filtering time: 0 ms for input, 3 ms for input, 12 ms for input Output voltage limits: 125 V DC, 277 V AC Maximum current per output common: 7 A Absolute accuracy error: +/- 1 % of full scale for analog input Electrical durability: 100000 cycles AC-12, 120 V, 240 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive 300000 cycles AC-12, 120 V, 80 VA, resistive 300000 cycles AC-12, 240 V, 160 VA, resistive 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive 100000 cycles DC-12, 24 V, 48 W, resistive 300000 cycles DC-12, 24 V, 16 W, resistive 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) Switching frequency: 20 switching operations/minute with maximum load Mechanical durability: 20000000 cycles for relay output Minimum load: 1 mA at 5 V DC for relay output Protection type: Without protection at 5 A Reset time: 1 s Memory capacity: 256 kB for user application and data RAM with 10000 instructions, 256 kB for internal variables RAM Data backed up: 256 kB built-in flash memory for backup of application and data Data storage equipment: 2 GB SD card (optional) Battery type: BR2032 lithium non-rechargeable, battery life: 4 year(s) Backup time: 1 year at 25 °C (by interruption of power supply) Execution time for 1 KInstruction: 0.3 ms for event and periodic task, 0.7 ms for other instruction Execution time per instruction: 0.2 µs Boolean Exct time for event task: 60 µs response time Application structure: 1 configurable freewheeling/cyclic master task, 1 cyclic auxiliary task, 8 interrupt tasks Maximum size of object areas: 255 %TM timers, 8000 %MW memory words, 255 %C counters, 512 %M memory bits, 512 %KW constant words Realtime clock: With Clock drift: <= 30 s/month at 25 °C Regulation loop: Adjustable PID regulator up to 14 simultaneous loops Counting input number: 4 fast input (HSC mode) at 100 kHz 32 bits Counter function: Pulse/direction, A/B, Single phase Integrated connection type: USB port with mini B USB 2.0 connector, Non isolated serial link serial 1 with RJ45 connector and RS485 interface, Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface Supply: (Serial 1)serial link supply: 5 V, <200 mA Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232, 480 Mbit/s for USB Communication port protocol: USB port: USB - SoMachine-Network, Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network Communication service: Modbus slave, Modbus master Local signalling: 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED per channel (green) for I/O state Electrical connection: Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal Removable screw terminal block, 10 terminal(s) for inputs Removable screw terminal block, 11 terminal(s) for outputs Maximum cable distance between devices: Shielded cable: <10 m for fast input Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input Insulation: Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Non-insulated between inputs Between output and internal logic at 500 V AC Between output groups at 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs Marking: CE Mounting support: Top hat type TH35-15 rail conforming to IEC 60715, Top hat type TH35-7.5 rail conforming to IEC 60715, Plate or panel with fixing kit Height: 90 mm Depth: 70 mm Width: 70 mm Product weight: 0.264 kg Shipping Weight: 3 Kg

Reviews

There are no reviews yet.

Be the first to review “TM221M16R Schneider Electric Logic controller, Modicon M221, 16 IO relay”

Your email address will not be published. Required fields are marked *