Manufacturer : Schneider Electric
logic controller, Modicon M241, 40 IO, transistor, NPN, Ethernet
Main
Range of product : Modicon M241
Product or component type : Logic controller
[Us] rated supply voltage : 24 V DC
Discrete input number : 24, discrete input 8 fast input conforming to IEC 61131-2 Type 1
Discrete output type : Transistor
Discrete output number : 16 transistor 4 fast output
Discrete output voltage : 24 V DC for transistor output
Discrete output current
0.1 A for fast output (PTO mode) (Q0…Q3)
0.5 A for transistor output (Q0…Q15)
Complementary
Discrete I/O number : 40
Maximum number of I/O expansion module
7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits : 20.4…28.8 V
Inrush current : 50 A
Power consumption in W : 32.6…40.4 W (with max number of I/O expansion module)
Discrete input logic : Sink or source
Discrete input voltage : 24 V
Discrete input voltage type : DC
Voltage state 1 guaranteed : >= 15 V for input
Voltage state 0 guaranteed : <= 5 V for input Discrete input current 10.7 mA for fast input 7 mA for input Input impedance 4.7 kOhm for input 2.81 kOhm for fast input Response time <= 2 µs turn-on, I0...I7 terminal(s) for fast input <= 2 µs turn-off, I0...I7 terminal(s) for fast input <= 2 µs turn-on, Q0...Q3 terminal(s) for fast output <= 2 µs turn-off, Q0...Q3 terminal(s) for fast output 50 µs turn-on, I0...I15 terminal(s) for input 50 µs turn-off, I0...I15 terminal(s) for input <= 34 µs turn-on, Q0...Q15 terminal(s) for output <= 250 µs turn-off, Q0...Q15 terminal(s) for output Configurable filtering time 1 µs for fast input 12 ms for fast input 0 ms for input 1 ms for input 4 ms for input 12 ms for input Discrete output logic : Negative logic (sink) Output voltage limits : 30 V DC Maximum current per output common : 2 A Maximum output frequency 20 kHz for fast output (PWM mode) 100 kHz for fast output (PLS mode) 1 kHz for output Accuracy +/- 0.1 % at 0.02…0.1 kHz for fast output +/- 1 % at 0.1…1 kHz for fast output Maximum leakage current : 5 µA for output Maximum voltage drop : <1 V Maximum tungsten load : <2.4 W Protection type Short-circuit protection Short-circuit and overload protection with automatic reset Reverse polarity protection for fast output Reset time 10 ms automatic reset output 12 s automatic reset fast output Memory capacity 8 MB for program 64 MB for system memory RAM Data backed up : 128 MB built-in flash memory for backup of user programs Data storage equipment : <= 16 GB SD card (optional) Battery type : BR2032 lithium non-rechargeable, battery life: 4 year(s) Backup time : 2 years at 25 °C Execution time for 1 KInstruction 0.3 ms for event and periodic task 0.7 ms for other instruction Application structure 8 external event tasks 3 cyclic master tasks + 1 freewheeling task 4 cyclic master tasks 8 event tasks Realtime clock : With Clock drift : <= 60 s/month at 25 °C Positioning functions PTO function 4 channel(s) (positioning frequency: 100 kHz) PTO function 4 channel(s) for transistor output (positioning frequency: 1 kHz) Counting input number 4 fast input (HSC mode) at 200 kHz 16 standard input at 1 kHz Control signal type A/B at 100 kHz for fast input (HSC mode) Pulse/direction at 200 kHz for fast input (HSC mode) Single phase at 200 kHz for fast input (HSC mode) Integrated connection type Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Non isolated serial link serial 2 with removable screw terminal block connector and RS485 interface USB port with mini B USB 2.0 connector Ethernet with RJ45 connector Supply : (Serial 1)serial link supply: 5 V, <200 mA Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for bus length of 3 m for USB 10/100 Mbit/s for Ethernet Communication port protocol : Non isolated serial link: Modbus master/slave Port Ethernet : 10BASE-T/100BASE-TX - 1 port(s) copper cable ethernet services FDR DHCP server via TM4 Ethernet switch network module DHCP client embedded Ethernet port SMS notifications Updating firmware SNMP client/server Programming NGVL Monitoring IEC VAR ACCESS FTP client/server Downloading SQL client Modbus TCP client I/O scanner Ethernet/IP originator I/O scanner embedded Ethernet port Ethernet/IP target, Modbus TCP server and Modbus TCP slave Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client Local signalling 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (red) for I/O error (I/O) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED (red) for bus fault on TM4 (TM4) 1 LED per channel (green) for I/O state 1 LED (green) for Ethernet port activity Electrical connection Removable screw terminal blockfor inputs and outputs (pitch 5.08 mm) removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm) Maximum cable distance between devices Unshielded cable: <50 m for input Shielded cable: <10 m for fast input Unshielded cable: <50 m for output Shielded cable: <3 m for fast output Insulation Between supply and internal logic at 500 V AC Non-insulated between supply and ground Between input and internal logic at 500 V AC Non-insulated between inputs Between fast input and internal logic at 500 V AC Between output and internal logic at 500 V AC Non-insulated between outputs Between fast output and internal logic at 500 V AC Between output groups at 500 V AC marking : CE Surge withstand 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 1 kV relay output differential mode conforming to EN/IEC 61000-4-5 1 kV input common mode conforming to EN/IEC 61000-4-5 1 kV transistor output common mode conforming to EN/IEC 61000-4-5 web services : Web server Maximum number of connections 8 Modbus server 8 SoMachine protocol 10 web server 4 FTP server 16 Ethernet/IP target 8 Modbus client Number of slave 64 Modbus TCP: 16 EtherNet/IP: Cycle time 10 ms 16 EtherNet/IP 64 ms 64 Modbus TCP Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit Height : 90 mm Depth : 95 mm Width : 190 mm Product weight : 0.62 kg Environment Standards ANSI/ISA 12-12-01 CSA C22.2 No 142 CSA C22.2 No 213 EN/IEC 61131-2:2007 Marine specification (LR, ABS, DNV, GL) UL 1604 UL 508 Product certifications CULus RCM CSA IACS E10 Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2 4 kV on contact conforming to EN/IEC 61000-4-2 Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 Resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4 1 kV (input) conforming to EN/IEC 61000-4-4 1 kV (transistor output) conforming to EN/IEC 61000-4-4 Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) Electromagnetic emission Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 Radiated emissions - test level: 40 dBμV/m QP class A at 30…230 MHz conforming to EN/IEC 55011 Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A at 230…1000 MHz conforming to EN/IEC 55011 Immunity to microbreaks : 10 ms Ambient air temperature for operation -10…50 °C (vertical installation) -10…55 °C (horizontal installation) Ambient air temperature for storage : -25…70 °C Relative humidity 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) IP degree of protection : IP20 with protective cover in place Pollution degree : 2 Operating altitude : 0...2000 m Storage altitude : 0…3000 m Vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail 3 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 3 gn at 8.4…150 Hz on panel mounting Shock resistance : 15 gn for 11 ms Shipping Weight : 1 Kg